Locomotive - 120V SOLUTION

 

Nominal Voltage Input:128V
Nominal Voltage Output:560Ah
Nominal Capacity:71.6 KWH
Weight: IP Rating: Dimension (mm)Battery Tank customised to locomotive design & weight requitements to IP 54 rating.
Cut-off Voltage (VDC):144.00 (Charging)
104.00 (Discharge)
Standard Current - Charge:280A
Time for Full Charge:< 180 min
Standard Current - Discharge:560A
Programmable Parameters:Above values are Max & Min, all values are programmable based on application
DC Connector - Charger:Anderson, with communication port
DC Connector - Locomotive:Specific to Locomotive, with communication port.
SOC Display:Voltage, Amp & SOC % Display
Cycles:6,000 Cycles (80% DOD recommended)
Operating Temperature:0~55 (c) Charge
'-20~55 (c) Discharge
Shelf Temperature:0~35 (c) 1 Year

 

  • BMS: Protection Function
    Over charge protection, over discharge protection, over current protection, short current protection, balanced function, temperature protection. 
  • Balancing - Active balancing with BMS.
  • Monitor - SOC, SOH, cell balance, cycle count.